MADI Interface for Digidesign
®
HD Systems
Installation and User Guide
82S6ALS20C
Solid State Logic
S O U N D
||
V I S I O N
Seitenansicht 0
1 2 3 4 5 6 ... 31 32

Inhaltsverzeichnis

Seite 1 - Solid State Logic

XXLLooggiicc DDeellttaa--LLiinnkk MMAADDII HHDDMADI Interface for Digidesign®HD SystemsInstallation and User Guide82S6ALS20CSolid State LogicS O U

Seite 2

Rear panelPrimary Port A Primary Port B USB Port Mains connectorMADI Port A output (left) MADI Port B output (left) WordClock inputand input (right)

Seite 3

7Primary Port A / Primary Port BEach Pro Tools®HD port provides 32 input and output channels, regardless of sample rate.MADI A / MADI BThe two MADI po

Seite 4

The Delta-Link MADI HD package includes:• The Delta-Link MADI HD unit.• 2 of 0.9m (35") DigiLink cables.• The mains connection cable.• This manua

Seite 5

91. In a typical setup, connect Primary Port A of the Delta-Link MADI HD to the Primary Port of your HD Core card andPrimary Port B of the Delta-Link

Seite 6

Pro Tools®HD cardThe Pro Tools®HD card is designed to operate as a Clock Slave, locking to a clock reference signal provided by the audio unitconnecte

Seite 7 - 1. Introduction

11WordClock / FrameClockThe WordClock input can translate WordClock or FrameClock to the required Sample Rate. The “LOCK” LED on the frontpanel indica

Seite 8 - Reading conventions

High Speed and SMUX modes• Sampling frequencies up to 48kHz are designated as being in the “NFS range” (from NFs, Normal Frequency sampling). • Sampli

Seite 9 - 2. Overview

13I/O mapping and Sample Rate rangeNFS range (44.1kHz to 48kHz): 64-48 “normal” modeTwo Primary Ports interact with one MADI Port.Primary Port A, chan

Seite 10 - Rear panel

NFS range (44.1kHz to 48kHz): 64-48 “special” modeTwo Primary Ports interact with two MADI Ports.Primary Port A, channel 01 ↔ MADI Port A, channel 01P

Seite 11

15DFS range (88.2kHz to 96kHz): 64-96 modeTwo Primary Ports interact with two MADI Ports.Primary Port A, channel 01 ↔ MADI Port A, channel 01Primary P

Seite 13 - WARNING!

QFS range (176.4kHz to 192kHz): 32-192 modeOne Primary Port interacts with two MADI Ports.Primary Port A, channel 01 ↔ MADI Port A, channel 01Primary

Seite 14 - 4. Synchronization

17General informationThe Delta-Link MADI HD can work with Pro Tools®HD systems running on a Windows PC or Macintosh OS X computer.Using the Delta-Link

Seite 15 - WordClock / FrameClock

The screenshot below was made using a Pro Tools®HD system with a single Delta-Link MADI HD which appears as a set of192 I/O peripherals (see below, to

Seite 16 - High Speed and SMUX modes

19Remote control of Delta-Link MADI HD settingsSome Delta-Link MADI HD system settings can be controlled via the Analog Out tab of the Pro Tools® soft

Seite 17

In the Hardware Setup window, the “Output Trim” settings are irrelevant to the Delta-Link MADI HD because its inputs andoutputs are all digital. There

Seite 18

21Known issuesStart up errorsWhen the Pro Tools® software starts up, it uses the settings defined during the previous session, e.g. number and type of

Seite 19

The best way to ensure all Legacy Interfaces are removed is to click the name of a Legacy Audio Interface (e.g. 882/20 or888/24) and to select “No Int

Seite 20

23Playback EngineThe Delta-Link MADI HD provides upto 64 input and output channels.Therefore, the number of voices for thePlayback Engine may

Seite 21 - Software

System ResourcesThe system resource usage can always be checked in thePro Tools®software under menu: Window|System Usage:Firmware UpdatesThe

Seite 22

25Symptoms Possible solutionsThe Delta-Link MADI HD is not detected by the software.Check that the Delta-Link MADI HD is connected to the mains supply

Seite 23 - Setup

Safety and Installation Considerations 11. Introduction 3XLogic Delta-Link MADI HD 3Reading conventions 42. Overview 5Front panel 5Rear panel 63. Ins

Seite 24

268. SpecificationsPhysical *Depth 175mm / 7" casing onlyHeight 44.5mm / 1.75" (1 RU)Width 438mm / 17.25" casing only482mm / 19" i

Seite 25 - Known issues

27This equipment has been tested and found to complywith the limits for a Class B digital device, pursuantto part 15 of the FCC Rules. These l

Seite 26

Solid State LogicS O U N D| |V I S I O NVisit SSL at URL: http://www.solidstatelogic.com© Solid State LogicAll Rights reserved under Inter

Seite 28 - 7. Troubleshooting

This section contains definitions, warnings, and practical information to ensure a safe working environment. Please take time to read this section bef

Seite 30 - 8. Specifications

3XLogic Delta-Link MADI HD Congratulations on your purchase of the XLogic Delta-Link MADI HD! Please be assured that it will provide you with manyyear

Seite 31 - OR HOME OR OFFICE USE

Reading conventionsSoftware menusWhere appropriate, to indicate a “path” under a Solid State Logic or Pro Tools®software menu, the following format wi

Seite 32

5Front panelPower switch Lock LED Power LEDPower switchThis switch is used to power the unit up or down.Power LEDThis LED is lit when the Delta-Link M