Solid State Logic 82S6PC1010C Bedienungsanleitung Seite 1

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Audiokarten Solid State Logic 82S6PC1010C herunter. Solid State Logic 82S6PC1010C User's Manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 76
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen

Inhaltsverzeichnis

Seite 2

Section 3 – Pre Installation InformationPhysical installation of the console is normally carried out by a specialised transportation company. In somec

Seite 3

Physical RequirementsConsole Control SurfaceThe console control surface can be specified to have from 8 to 96 channels so the size and weight will var

Seite 4

Page 8C100 Installation Guide105680 min.7320-4517 24 Master 91618283640956988177633425 325332 Channel FootprintSide Profile Showing Service AccessMe

Seite 5 - Contents

Air Conditioning RequirementsAir conditioning will almost certainly be required for both the Machine and Control rooms in order to maintainthe tempera

Seite 6 - Section 1 – Introduction

Page 10C100 Installation GuideCenturi Processor Crate (side view) Showing Card AccessC-SB Crate (side view) Showing Card AccessDimensions in mm592 270

Seite 7 - Electrical Safety Warning

Technical RequirementsVideo Sync SourceThe Centuri Processor requires a feed of video sync. Other sources – MIDI or wordclock etc. – cannot be used as

Seite 8

Page 12C100 Installation GuidePA NA FLPFLO NCLRMODEA /B< >A TTDELA YINS ER T-20-18-15-12-9-6-3-2-10ATTA C KRE LEA SEsam plesfram esm sGATE /EXPA

Seite 9 - FCC Certification

Section 4 – System ComponentsThis section gives an overview of the main units in the system. See Appendix A for specifications andApp

Seite 10 - Services provided by SSL

Page 14C100 Installation GuideIOIOMACHINECONTROLTIMECODECONTROLSURFACE 1CONTROLSURFACE 2CONTROLSURFACE 39 - 16 1 - 825 - 32 17 - 249 - 16 1 - 825 -

Seite 11 - Physical Requirements

The Centuri ProcessorThe Centuri processor is a 15U high 600mm deep rack unit. Cards are fitted to the front and rear of the chassisso space for acces

Seite 13

Page 16C100 Installation GuideETHERNETVIDEO 3VIDEO 2SYNCVIDEO 1960XASERIAL+5V+3V3FLAG 1FLAG 12RESETSolid State LogicO X F O R D • E N G L A N DDSP CAR

Seite 14 - Dimensions in mm

Centuri – DSP CardThe DSP cards supply the signal processing function for the Centuri system. Each card provides 32 channels ofprocessing. DSP cards a

Seite 15 - Technical Requirements

Page 18C100 Installation GuideINOUT1 - 1213 - 2425 - 3637 - 4849 - 601 - 1213 - 2425 - 3637 - 4849 - 60GPI907XA9 - 161 - 825 - 3217 - 24AES/EBU IN9 -

Seite 16 - 100 Channel Bay Layout

Centuri – Micamp CardThe Microphone input card (generally known as the BMA or ‘Broadcast Mic Amp’) provides 12 input channels.The input is via a femal

Seite 17 - Section 4 – System Components

Page 20C100 Installation Guide+48VSIGOVERLOADSELECT+48VSIGOVERLOADSELECT+48VSIGOVERLOADSELECT+48VSIGOVERLOADSELECT+48VSIGOVERLOADSELECT+48VSIGOVE

Seite 18 - Centuri Processor Crate

C-SB Stagebox (option)The C-SB is a Mic/Line input/output stagebox which can be located remotely from the Centuri chassis. Itoperates

Seite 19 - The Centuri Processor

Page 22C100 Installation GuideSolid State LogicNetBridgeSERIAL 1 - 8TERMINALSERIAL 9 230 SSLTCP/IP Model Serial No. Solid State Logic  Oxfor

Seite 20 - Solid State Logic

NetBridge (option)NetBridge is a 2U rack mounting unit.The NetBridge provides two main features. Firstly (as the name suggests) it is a bridge between

Seite 21

Page 24C100 Installation GuideETHER 1ETHER 2ETHER 3ETHER 4T/SCRMIC GNCTRL 1CTRL 2CTRL 3BT/PADKBDUSBLocation Of Bellypanel USB Connectors

Seite 22

External Keyboard / Trackball (options)There is an inbuilt software keyboard included in the C100 system. This is accessed via the Centre Section touc

Seite 23

Solid State LogicDigital Broadcast ConsoleInstallation GuideVersion 1.2.082S6PC1010C

Seite 24 - O X F O R D • E N G L A N D

Page 26C100 Installation GuidePOWER INPOWER INBACKUPConsole Mains Inlet PanelCenturi Mains Inlet PanelNetBridge Rear PanelIOIOCONSOLEPOWERINDICATOR

Seite 25 - MORSE System (option)

Section 5 – Installation WiringThis section provides the details for connecting the system components together.Power Supply ConnectionsThis section re

Seite 26 - NetBridge (Rear View)

Page 28C100 Installation Guide960XAMACHINECONTROLTIMECODECONTROLSURFACE 1CONTROLSURFACE 2CONTROLSURFACE 3906XASYNCVIDEO 3VIDEO 2VIDEO 1ETHERNETSERI

Seite 27 - NetBridge (option)

Centuri to Console Surface ConnectionsThis section refers to the following supplied items:Description SSL Part No. qty NoteLead 9WD plug to 9WD plug 1

Seite 28 - C100 Installation Guide

Page 30C100 Installation GuideSYNCPSU Status Wiring DiagramIOIOCONSOLEPOWERINDICATORSREMOTEPOWERINDICATORSPSU 1PSU 1EXT T/BMIC INTALKBACKOUTPUTX

Seite 29 - TFT External Input (option)

PSU StatusThis section refers to the following supplied items:Description SSL Part No. qty NoteCable 25-way D Plug to Socket 16m screened66C677811a) T

Seite 30 - NetBridge Rear Panel

Page 32C100 Installation Guide+5V1-67-12SPLIT OUTPUTSMIC IN1 - 12908XAAA1A1ANALOGUE IN1 - 24ANALOGUE OUT1 - 24904XAMicamp Input CardAnalogue I/O Ca

Seite 31 - 66C93115

I/O – MicAmp Card (SSL ref. 908)Each MicAmp Input Card contains 12 Microphone circuits. The inputs are accessed via a Varicon (aka. EDAC orElco) 56-wa

Seite 32 - TTY-C TTY-G TTY-B

Page 34C100 Installation Guide9 - 161 - 825 - 3217 - 24AES/EBU IN9 - 161 - 825 - 3217 - 24902XBAES/EBU OUTINOUTWORDSYNCINOUTAESSYNCTxRxTxRxLOCKALOCK

Seite 33

I/O – Digital Input/Output Card 110Ω (SSL ref. 902XF)The Digital Input Card provides 32 balanced AES/EBU signal pairs of both input and output. All ci

Seite 34 - CPU Card

C100 Installation GuideSolid State LogicS O U N D||V I S I O NBegbroke, Oxford, England, OX5 1RU • +44 (0)1865 842300320 West 46th Street, 2nd Floor,

Seite 35 - 32TKU7CC

Page 36C100 Installation GuideGPI I/O CardINOUT1 - 1213 - 2425 - 3637 - 4849 - 601 - 1213 - 2425 - 3637 - 4849 - 60GPI907XAGPI input Connectors25-way

Seite 36

Installation WiringSection 5Page 37I/O – GPI I/O (SSL ref. 907XA)The GPI I/O Card contains 60 circuits of opto-isolated input and 60 circuits of relay

Seite 37

C-SBLCFibre i/f 1aNetworkLCFibre i/f 1aNetworkEthernet hub/switchCenturiProcessorC-SBLCFibre i/f 1aNetworkLCFibre i/f 1aNetworkEthernet hub/switchCent

Seite 38 - (Copper version)

Stageboxes & Fibre LinksThe C-SB Stagebox utilises fibre-optic connection between itself and the Centuri Processor. This has theadva

Seite 39

Page 40C100 Installation GuideSERIAL 1 - 8TERMINALSERIAL 9 230 SSLTCP/IP Model Serial No. Solid State Logic Oxford • England FUSE risk of

Seite 40 - GPI I/O Card

NetBridge InstallationNetBridge has eight serial ports plus two Ethernet ports. The first Ethernet port is connected to the C100’snet

Seite 41

Page 42C100 Installation GuideEXT T/BMIC INTALKBACKOUTPUTX1X2D5PUSHMIC GNCTRL 3USBInternalT/BMicExternalT/BMic inAnalogueI/O cardC100 ConsoleTalkback

Seite 42 - C-SB Cabling Diagrams

Talkback and OscillatorTalkback ConnectionsThe C100 console contains a built-in talkback microphone and amplifier. In addition, a second input is avai

Seite 43 - Stageboxes & Fibre Links

Page 44C100 Installation GuideMeter and Phasescope wiring - MSD 600CMeter and Phasescope wiring - RTW 10830REMOTEPOWER INPHASESCOPEMETERINPUTSMSDD

Seite 44 - NetBridge Installation

Installation WiringSection 5Page 45Meters and PhasescopeThe Centre Section of the C100 console may optionally be fitted with an LCD phasescope and/or

Seite 45

Contents1Introduction 22Safety Considerations 3Safety Warnings 4CE/FCC/WEEE Certification and Directives 53Pre-Installation Information 6Services Prov

Seite 46

Page 46C100 Installation GuideGold is 1.9 times heavier than Lead.

Seite 47 - Talkback and Oscillator

Appendix A – SpecificationsPage 47Appendix A: SpecificationsC100 ConsoleParameter Condition Value Unit NotesHeight To top of meter trim 1,056 mmHeight

Seite 48

Page 48C100 Installation GuideCenturi Processor CrateParameter Condition Value Unit NotesHeight: 15 U665 mmWidth 19 inCase w/o rack ears 449 mmDepth 5

Seite 49 - Meters and Phasescope

Appendix A – SpecificationsPage 49Net BridgeParameter Condition Value Unit NotesHeight: 2 U89mmWidth: 19 inCase w/o rack ears 432 mmDepth 360 mm Exclu

Seite 50

Page 50C100 Installation Guide(1) Ventilation is convection via vents at top and bottom of front panel. Do not obstruct vents – refer toAppendix F for

Seite 51 - Appendix A: Specifications

Appendix B – Connector DetailsPage 51Appendix B: Connector DetailsHoodHoodPlugFree Socket Free PlugConnectors Viewed From Wiring SideConnectors Viewed

Seite 52

Page 52C100 Installation GuideConnectors Viewed From Wiring Side12345141516176789101819202111121322232425123451415161767891018192021111213222324251234

Seite 53 - Net Bridge

Appendix C – Connector PinoutsPage 53Appendix C: Connector Pinouts – C100 Console'Meter Inputs' (Analogue)Location:'Audio' interfa

Seite 54 - -SB Micamp Rack

Page 54C100 Installation Guide'Phase Scope' (Digital)Location: 'Audio' Console Belly PanelConnector Type: 25-way D-type female

Seite 55 - Appendix B: Connector Details

Appendix C – Connector PinoutsPage 55Connector Pinouts – Centuri Processor'Video 1, 2 and 3'Location: Centuri - CPU CardConnector Type: HD15

Seite 56

Section 1 – IntroductionThe object of this manual is to provide purchasers of the C100™ Console and Centuri™ Processor withinformation in the followin

Seite 57

Page 56C100 Installation Guide'Serial'Location:Centuri – CPUConnector Type:62-pin High-density D-type female D9 pin no. Description10V6

Seite 58

Appendix C – Connector PinoutsPage 57Mic Input Card (‘908)+5V1-67-12SPLIT OUTPUTSMIC IN1 - 12908XAAMic IN 1 - 12Location: 908 MicampConnector Type: V

Seite 59 - 'MIDI'

Page 58C100 Installation GuideAnalogue I/O Card (‘904)Analogue IN / Analogue OUTLocation:904 Analogue I/OConnector Type:DL96 Femalecct.hotcoldscreenNo

Seite 60 - 'TTYE' (RS232)

Appendix C – Connector PinoutsPage 599 - 161 - 825 - 3217 - 24AES/EBU IN9 - 161 - 825 - 3217 - 24902XBAES/EBU OUTDigital I/O Card (‘902)BNC Breakout P

Seite 61 - Mic Input Card (‘908)

Page 60C100 Installation GuideGPI I/O Card (‘907)INOUT1 - 1213 - 2425 - 3637 - 4849 - 601 - 1213 - 2425 - 3637 - 4849 - 60GPI907XAGPI Inputs 1 - 12 (1

Seite 62 - Analogue I/O Card (‘904)

Appendix C – Connector PinoutsPage 61Connector Pinouts – NetBridgeScreenChassisTx DataGndRx Datan/cn/cn/c9-wayFemaleD-typen/cn/cn/cRx Datan/cTx Datan/

Seite 63 - Digital I/O Card (‘902)

Page 62C100 Installation GuideResistor Colour Code:Black 0Brown 1Red 2Orange 3Yellow 4Green 5Blue 6Violet 7Grey 8White 9

Seite 64 - GPI I/O Card (‘907)

Appendix D – Audio InterfacingPage 63Appendix D: Audio InterfacingAll analogue audio inputs and outputs are electronically balanced. The screen pins a

Seite 65 - Connector Pinouts – NetBridge

Page 64C100 Installation Guide1 inch = 25.4mm (exactly)1m = 3’ 3” (roughly)1 mile = 1,600m (roughly)1Kg = 2.2 Pounds (roughly)

Seite 66

Appendix E – Environmental SpecificationsPage 65Temperature Operating: 5 to 30 Deg. CNon-operating: -20 to 50 Deg. CMax. Gradient: 15 Deg. C/HourRelat

Seite 67 - Appendix D: Audio Interfacing

Section2 – Safety ConsiderationsThis section contains definitions and warnings, and practical information to ensure a safe working environment.Please

Seite 68

C100 Installation GuidePage 66+4dBu = 1.229V rms.0dBu = 0.775V rms.-6dBu = 0.388V rms.

Seite 69

Appendix F – Stagebox InstallationPage 67Appendix F: Additional Information for Installing StageboxesWhen positioning and installing C-SB the followin

Seite 70 - -6dBu = 0.388V rms

C100 Installation GuidePage 68This page is blank intentionally.

Seite 71

Appendix G – Part NumbersPage 69Appendix G: Cables and accessoriesCables and Accessories - by Part DescriptionDescription SSL Part No. Audio Cables an

Seite 72

C100 Installation GuidePage 70Appendix E – Environmental SpecificationDescription SSL Part No. Video & SyncLead Video HD15 XGA 16m 66DN16V1Lead Vi

Seite 73

Appendix G – Part NumbersPage 71Notes

Seite 74

C100 Installation GuidePage 72More Notes

Seite 75 - Appendix G – Part Numbers

Safety Earth ConnectionAny mains powered item of SSL equipment that is supplied with a 3-core mains lead (whether connectorised ornot) should always h

Seite 76

CE CertificationNote that the majority of cables supplied with SSL equipment are fitted with ferrite rings at each end.This is to comply with current

Kommentare zu diesen Handbüchern

Keine Kommentare